Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 11.229
Filtrar
1.
Clin Orthop Surg ; 16(2): 313-321, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38562625

RESUMO

Background: Although several techniques for the treatment of ulnar impaction syndrome (UIS) have been introduced, there have still been reports on various complications such as delayed union, nonunion, refracture, wrist pain, plate irritation, and chronic regional pain syndrome. This study aimed to compare the differences in radiological and clinical outcomes of patients in which intramedullary bone grafting was performed in addition to plate stabilization with those without additional bone grafting during ulnar shortening osteotomies (USOs). Methods: Between November 2014 and June 2021, 53 wrists of 50 patients with idiopathic UIS were retrospectively reviewed. Patients were divided into 2 groups according to whether intramedullary bone grafting was performed. Among the 53 wrists, USO with an intramedullary bone graft was performed in 21 wrists and USO without an intramedullary bone graft was performed in 32 wrists. Demographic data and factors potentially associated with bone union time were analyzed. Results: There was no significant difference between the 2 groups when comparing postoperative radioulnar distance, postoperative ulnar variance, amount of ulnar shortening, and postoperative Disabilities of the Arm, Shoulder and Hand score. Compared to the without-intramedullary bone graft group, bone union time of the osteotomy site was significantly shortened, from 8.8 ± 3.0 weeks to 6.7 ± 1.3 weeks in the with-intramedullary bone graft group. Moreover, there were no cases of nonunion or plate-induced symptoms. Both in univariable and multivariable analyses, intramedullary bone grafting was associated with shorter bone union time. Conclusions: USO with an intramedullary bone graft for idiopathic UIS has favorable radiological and clinical outcomes. The advantage of this technique is the significant shortening of bone union time.


Assuntos
Artropatias , Articulação do Punho , Humanos , Estudos Retrospectivos , Articulação do Punho/diagnóstico por imagem , Articulação do Punho/cirurgia , Transplante Ósseo , Resultado do Tratamento , Ulna/diagnóstico por imagem , Ulna/cirurgia , Artropatias/cirurgia , Osteotomia/métodos
2.
Medicine (Baltimore) ; 103(16): e37915, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38640286

RESUMO

RATIONALE: Acute blockage of forearm supination has been reported in several studies. It is caused by loose bodies in the wrist joint, extensor carpi ulnaris tendon interposition, and distal radioulnar joint (DRUJ) injuries, including forearm bone fractures. Some studies have reported cases of DRUJ injuries caused by triangular fibrocartilage complex (TFCC) tears.We report a case of acute blockage of forearm supination after minor trauma and suggest a possible TFCC tear when a patient complains of forearm supination blocking. In addition, we present a comparison between our case and other reports on etiology, magnetic resonance imaging (MRI) findings, and arthroscopic findings, and show the specific characteristics of our case. PATIENTS CONCERNS: A 22-year-old male presented with left wrist pain as the chief complaint. He was injured 2 months prior to pushing his left hand on the floor during exercise. Physical examination showed a relative limitation of range of motion (ROM) in the left wrist of about 10° in flexion and about 15° in extension compared with the right side. The patient also complained of supination limitation and volar side wrist pain during supination. The patient showed tenderness in the axial compression test. DIAGNOSES: Plain radiographs showing no abnormalities. MRI showed a TFCC tear in the central portion. A torn flap of the TFCC was interposed on the volar side of the DRUJ. INTERVENTIONS: Arthroscopic surgery of the left wrist joint was performed. Arthroscopic examination revealed a tear in the TFCC on the radial side. A torn flap was interposed on the volar side of the DRUJ. We removed the flap from the DRUJ using an arthroscopic grasper and partially resected it. OUTCOMES: Intraoperative tests showed no locking and the forearm was well supinated. Two months after the surgery, the patient had no pain and showed full forearm supination. LESSONS: DRUJ blocking due to a TFCC tear should be suspected when acute blockage of forearm supination occurs after minor trauma. MRI is helpful for diagnosis; however, we suggest that the diagnosis should be confirmed through arthroscopy. Symptoms can be resolved by surgical treatment using arthroscopy.


Assuntos
Instabilidade Articular , Lesões do Menisco Tibial , Fibrocartilagem Triangular , Traumatismos do Punho , Masculino , Humanos , Adulto Jovem , Adulto , Fibrocartilagem Triangular/cirurgia , Fibrocartilagem Triangular/lesões , Fibrocartilagem Triangular/patologia , Antebraço/patologia , Supinação , Lesões do Menisco Tibial/patologia , Articulação do Punho/diagnóstico por imagem , Articulação do Punho/cirurgia , Articulação do Punho/patologia , Traumatismos do Punho/diagnóstico , Dor/patologia , Artralgia/patologia , Artroscopia/métodos , Instabilidade Articular/patologia
3.
Sensors (Basel) ; 24(7)2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38610578

RESUMO

The aim of this paper is to investigate technological advancements made to a robotic tele-ultrasound system for musculoskeletal imaging, the MSK-TIM (Musculoskeletal Telerobotic Imaging Machine). The hardware was enhanced with a force feedback sensor and a new controller was introduced. Software improvements were developed which allowed the operator to access ultrasound functions such as focus, depth, gain, zoom, color, and power Doppler controls. The device was equipped with Wi-Fi network capability which allowed the master and slave stations to be positioned in different locations. A trial assessing the system to scan the wrist was conducted with twelve participants, for a total of twenty-four arms. Both the participants and radiologist reported their experience. The images obtained were determined to be of satisfactory quality for diagnosis. The system improvements resulted in a better user and patient experience for the radiologist and participants. Latency with the VPN configuration was similar to the WLAN in our experiments. This research explores several technologies in medical telerobotics and provides insight into how they should be used in future. This study provides evidence to support larger-scale trials of the MSK-TIM for musculoskeletal imaging.


Assuntos
Sistema Musculoesquelético , Robótica , Humanos , Ultrassonografia , Sistema Musculoesquelético/diagnóstico por imagem , Articulação do Punho , Software
4.
BMC Musculoskelet Disord ; 25(1): 217, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38491493

RESUMO

Traditionally, the assessment of distal radius fracture outcomes has been based on radiological measurements and self-evaluation scores. However, there is uncertainty regarding how accurately these measurements reflect the patient's perception of their outcome. In this study, we examined the correlation between radiological measurements and patient-perceived outcomes using the Disabilities of the Arm, Shoulder, and Hand outcome (DASH) score. 140 individuals who had recovered from a distal radius fracture. and had been treated with DVR, Kapandji, percutaneous pinning or closed reduction were included in the study. The retrospective assessment included 78 females and 62 males, with a mean DASH score of 3.54 points.Except for the ulnar variance, the study found little to no significant association between the DASH score and the final radiological measurement.In summary, the DASH score did not always indicate that a superior radiological result translated into a better patient-perceived outcome.


Assuntos
Fraturas do Rádio , Fraturas do Punho , Traumatismos do Punho , Masculino , Feminino , Humanos , Punho , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Estudos Retrospectivos , Articulação do Punho , Traumatismos do Punho/diagnóstico por imagem , Traumatismos do Punho/cirurgia , Amplitude de Movimento Articular , Fixação Interna de Fraturas , Placas Ósseas , Resultado do Tratamento
5.
Sci Rep ; 14(1): 7111, 2024 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-38531907

RESUMO

This study aims to measure anatomical data of the capitate bone, develop an external fixator for treating late-stage osteonecrosis of lunate through Ilizarov technique, and evaluate its biomechanical performance. We selected eight wrist joint specimens to measure various parameters of the capitate bone, including its length, the distance from the junction of capitate head and body to the proximal end, as well as the width of its proximal head and distal body. Additionally, we measured these same indicators in 107 patients who had undergone wrist X-ray examination. Based on our measurements, we categorized the capitate bone into two groups and designed two types of capitate bone Ilizarov external fixator (CIEF) for it. Then, we compared it with the orthofix external fixator (OEF) through dynamic fatigue biomechanical experiments and pull-out resistance experiments. The results of the measurement revealed two categories of general patterns in the capitate bone. The first type maintains a consistent longitudinal axis between the proximal and distal ends. The second type is characterized by its proximal end being close to the radial side and its distal end being close to the ulnar side. In the dynamic tensile fatigue test, CIEF-A and CIEF-B had smaller maximum displacement values compared to the OEF (P < 0.05). In the anti-pull-out experiment, both CIEF-A and CIEF-B exhibited higher maximum pull-out force than the OEF (P < 0.05). CIFE is a treatment for advanced osteonecrosis of the lunate bone. It is specifically designed to align with the anatomical characteristics of the capitate bone, providing excellent biomechanical properties and a simple clinical procedure. However, additional clinical experiments are needed to confirm its effectiveness in the future.


Assuntos
Capitato , Osso Semilunar , Osteonecrose , Humanos , Osteonecrose/cirurgia , Articulação do Punho/cirurgia , Rádio (Anatomia)
6.
Acta Orthop Traumatol Turc ; 58(1): 27-33, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38525507

RESUMO

OBJECTIVE: We aimed to define minimal clinically important difference (MCID) values of patient-reported outcome measures (PROMs) for distal metaphyseal ulnar shortening and to assess the relationship between level of the osteotomy and time to bone union. METHODS: 20 patients who had distal metaphyseal ulnar shortening osteotomies due to ulnar impaction syndrome and had at least 6 months of follow-ups were included in this study. The mean follow-up period was 12.3 ± 7.01 months. The PROMs which consisted of patient-rated wrist evaluation (PRWE) and quick disabilities of arm, shoulder, and hand (QDASH) were recorded on the day before the surgery and at follow-up assessments. Grip strength and range of motion were recorded for operated and contralateral wrists at postoperative assessments. Postoperative radiological evaluations of distance of the osteotomy from the distal ulnar articular surface (osteotomy level), the union of osteotomy site; preoperative and postoperative evaluations of styloid-triquetral distance, and ulnar variance were performed using AP wrist x-rays. The MCID values for PRWE and QDASH were calculated using ROC curve analysis. RESULTS: Mean PRWE and QDASH scores decreased statistically significantly. The mean grip strength of contralateral wrists was higher. Mean ulnar variance decreased, whereas styloid-triquetral distance increased postoperatively. Patients with osteotomy levels of greater than 13.7 mm had a longer time from surgery to bone union. Furthermore, patients with time from surgery to bone union shorter than 7 weeks had an osteotomy closer to the ulnar articular surface. The MCID values for PRWE and QDASH were analyzed and calculated through the ROC curve as 22.25 and 20.45, respectively. CONCLUSION: This study has shown us that the osteotomy level affects the time to bone union and an osteotomy closer than 13.7 mm to the ulnar articular surface seems to result in shorter union time. Furthermore, MCID values were defined for PRWE and QDASH as 22.25 and 20.45, respectively. LEVEL OF EVIDENCE: Level IV, Therapeutic Study.


Assuntos
Artropatias , Humanos , Resultado do Tratamento , Artropatias/cirurgia , Osteotomia , Articulação do Punho/diagnóstico por imagem , Articulação do Punho/cirurgia , Ulna/diagnóstico por imagem , Ulna/cirurgia , Amplitude de Movimento Articular , Estudos Retrospectivos
7.
8.
J Pediatr Orthop ; 44(5): 333-339, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38450641

RESUMO

BACKGROUND: Severe spastic wrist contractures secondary to cerebral palsy (CP) or alike can have significant implications for patient hand function, hygiene, skin breakdown, and cosmesis. When these contractures become rigid, soft tissue procedures alone are unable to obtain or maintain the desired correction. In these patients' wrist arthrodesis is an option-enabling the hand to be stabilized in a more functional position for hygiene, dressing, and general cosmesis, though are patients satisfied? METHODS: All children who had undergone a wrist arthrodesis for the management of a severe wrist contracture at Shriners Hospital, Portland between January 2016 and January 2021 were identified (n=23). A chart review was undertaken to obtain data-demographic, operative, clinical, and radiographic. All patients were then contacted to participate in 2 patient-reported outcome questionnaires (74% response agreement), a numerical rating scale (NRS), based on the visual analog scale (VAS) and the disability analog scale (DAS). Results were assessed with the aid of descriptive statistics, means and percentages with the primary focus of determining overall patient satisfaction with the procedure. RESULTS: Twenty-three patients were included in the review, and 74% took part in the prospective survey. Included were 10 patients with hemiplegia, 4 with triplegia, 7 with quadriplegia, 1 with a diagnosis of Rhett syndrome, and 1 with a history of traumatic brain injury. All patients achieved radiologic union by a mean of 8 weeks, and 87% obtained a neutral postoperative wrist alignment. The NRS showed 88% of patients were highly satisfied with their results; specifically, 82% had an improved appearance, 53% improved function, 71% improved daily cares, and 65% improved hygiene. The postoperative DAS score averaged 4.7 of 12 indicating mild disability. When looking at how a patient's diagnostic subtype affected outcome results, patients with triplegia reported less improvement and greater disability on the NRS and DAS, averaging 9.5 (severe disability on the DAS). The GMFCS classification had less correlation with outcomes. CONCLUSION: Wrist arthrodesis is a good option for the management of pediatric spastic wrist contractures, with limited complications and an overall high patient/carer satisfaction rate. LEVEL OF EVIDENCE: Level IV-case series.


Assuntos
Contratura , Punho , Humanos , Criança , Espasticidade Muscular/cirurgia , Espasticidade Muscular/complicações , Estudos Prospectivos , Estudos Retrospectivos , Articulação do Punho/diagnóstico por imagem , Articulação do Punho/cirurgia , Contratura/etiologia , Contratura/cirurgia , Artrodese/métodos , Resultado do Tratamento
9.
PLoS One ; 19(3): e0300469, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38512857

RESUMO

INTRODUCTION: The Delft Self-Grasping Hand (SGH) is an adjustable passive hand prosthesis that relies on wrist flexion to adjust the aperture of its grasp. The mechanism requires engagement of the contralateral hand meaning that hand is not available for other tasks. A commercialised version of this prosthesis, known as the mHand Adapt, includes a new release mechanism, which avoids the need to press a release button, and changes to the hand shape. This study is the first of its kind to compare two passive adjustable hand prostheses on the basis of quantitative scoring and contralateral hand involvement. METHODS: 10 anatomically intact participants were asked to perform the Southampton Hand Assessment Procedure (SHAP) with the mHand. Functionality and contralateral hand involvement were recorded and compared against SGH data originating from a previous trial involving a nearly identical testing regime. RESULTS: mHand exhibited higher functionality scores and less contralateral hand interaction time, especially during release-aiding interactions. Additionally, a wider range of tasks could be completed using the mHand than the SGH. DISCUSSION: Geometric changes make the mHand more capable of manipulating smaller objects. The altered locking mechanism means some tasks can be performed without any contralateral hand involvement and a higher number of tasks do not require contralateral involvement when releasing. Some participants struggled with achieving a good initial grip due to the inability to tighten the grasp once already formed. CONCLUSION: The mHand offers the user higher functionality scores with less contralateral hand interaction time and the ability to perform a wider range of tasks. However, there are some design trade-offs which may make it slightly harder to learn to use.


Assuntos
Membros Artificiais , Mãos , Humanos , Aprendizagem , Articulação do Punho , Punho , Força da Mão
10.
Sensors (Basel) ; 24(5)2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38475215

RESUMO

Increasing age is related to a decrease in independence of movement and with this decrease comes falls, millions of falls occur every year and the most affected people are the older adults. These falls usually have a big impact on health and independence of the older adults, as well as financial impact on the health systems. Thus, many studies have developed fall detectors from several types of sensors. Previous studies related to the creation of fall detection systems models use only one dataset that usually has a small number of samples. Training and testing machine learning models in this small scope: (i) yield overoptimistic classification rates, (ii) do not generalize to real-life situations and (iii) have very high rate of false positives. Given this, the proposal of this research work is the creation of a new dataset that encompasses data from three different datasets, with more than 1300 fall samples and 28 K negative samples. Our new dataset includes a standard way of adding samples, which allow the future addition of other data sources. We evaluate our dataset by using classic cost-sensitive Machine Leaning methods that deal with class imbalance. For the training and validation of this model, a set of temporal and frequency features were extracted from the raw data of an accelerometer and a gyroscope using a sliding window of 2 s with an overlap of 50%. We study the generalization properties of each dataset, by testing on the other datasets and also the performance of our new dataset. The model showed a good ability to distinguish between activities of daily living and falls, achieving a recall of 90.57%, a specificity of 96.91% and an Area Under the Receiver Operating Characteristic curve (AUC-ROC) value of 98.85% against the combination of three datasets.


Assuntos
Atividades Cotidianas , Punho , Humanos , Idoso , Movimento , Articulação do Punho , Algoritmos
11.
BMC Musculoskelet Disord ; 25(1): 198, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38443916

RESUMO

BACKGROUND: This meta-analysis aims to investigate the efficacy of early rehabilitation on patients who have undergone surgery for distal radius fractures (DRFs) with palmar plating, focusing on multiple outcome measures including upper limb function, wrist function, back extension mobility, pain levels, and complications. METHODS: A rigorous search strategy adhering to the PRISMA guidelines was employed across four major databases, including PubMed, Embase, Web of Science, and the Cochrane Library. Studies were included based on stringent criteria, and data extraction was performed independently by two reviewers. Meta-analysis was conducted employing both fixed-effect and random-effects models as dictated by heterogeneity, assessed by the I2 statistic and chi-square tests. A total of 7 studies, encompassing diverse demographic groups and timelines, were included for the final analysis. RESULTS: The meta-analysis disclosed that early rehabilitation yielded a statistically significant improvement in upper limb function (SMD -0.27; 95% CI -0.48 to -0.07; P < 0.0001) and back extension mobility (SMD 0.26; 95% CI 0.04 to 0.48; P = 0.021). A notable reduction in pain levels was observed in the early rehabilitation group (SMD -0.28; 95% CI -0.53 to -0.02; P = 0.03). However, there were no significant differences in wrist function (SMD -0.13; 95% CI -0.38 to 0.12; P = 0.36) and complications (OR 0.99; 95% CI 0.61 to 1.61; P = 0.96). CONCLUSIONS: Early rehabilitation post-DRF surgery with palmar plating has been found to be beneficial in enhancing upper limb functionality and back extension mobility, and in reducing pain levels. Nevertheless, no significant impact was observed regarding wrist function and complications.


Assuntos
Fraturas do Punho , Humanos , Dor , Extremidade Superior , Punho , Fraturas do Punho/reabilitação , Articulação do Punho
12.
J Neuroeng Rehabil ; 21(1): 39, 2024 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-38515192

RESUMO

BACKGROUND: Effective stroke rehabilitation requires high-dose, repetitive-task training, especially during the early recovery phase. However, the usability of upper-limb rehabilitation technology in acute and subacute stroke survivors remains relatively unexplored. In this study, we introduce subacute stroke survivors to MyoGuide, a mobile training platform that employs surface electromyography (sEMG)-guided neurofeedback training that specifically targets wrist extension. Notably, the study emphasizes evaluating the platform's usability within clinical contexts. METHODS: Seven subacute post-stroke patients (1 female, mean age 53.7 years, mean time post-stroke 58.9 days, mean duration per training session 48.9 min) and three therapists (one for eligibility screening, two for conducting training) participated in the study. Participants underwent ten days of supervised one-on-one wrist extension training with MyoGuide, which encompassed calibration, stability assessment, and dynamic tasks. All training records including the Level of Difficulty (LoD) and Stability Assessment Scores were recorded within the application. Usability was assessed through the System Usability Scale (SUS) and participants' willingness to continue home-based training was gauged through a self-developed survey post-training. Therapists also documented the daily performance of participants and the extent of support required. RESULTS: The usability analysis yielded positive results, with a median SUS score of 82.5. Compared to the first session, participants significantly improved their performance at the final session as indicated by both the Stability Assessment Scores (p = 0.010, mean = 229.43, CI = [25.74-433.11]) and the LoD (p < 0.001; mean: 45.43, CI: [25.56-65.29]). The rate of progression differed based on the initial impairment levels of the patient. After training, participants expressed a keen interest in continuing home-based training. However, they also acknowledged challenges related to independently using the Myo armband and software. CONCLUSIONS: This study introduces the MyoGuide training platform and demonstrates its usability in a clinical setting for stroke rehabilitation, with the assistance of a therapist. The findings support the potential of MyoGuide for wrist extension training in patients across a wide range of impairment levels. However, certain usability challenges, such as donning/doffing the armband and navigating the application, need to be addressed to enable independent MyoGuide training requiring only minimal supervision by a therapist.


Assuntos
Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Humanos , Feminino , Pessoa de Meia-Idade , Punho , Reabilitação do Acidente Vascular Cerebral/métodos , Extremidade Superior , Articulação do Punho
13.
Arch Orthop Trauma Surg ; 144(4): 1603-1609, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38441618

RESUMO

INTRODUCTION: Distal radioulnar joint (DRUJ) instabilities are challenging and their optimal treatment is controversial. In special cases or when reconstruction of the stabilizing triangular fibrocartilage complex (TFCC) fails, K-wire transfixation can be performed. However, no consensus has been reached regarding the rotational position of the forearm in which this should be done. Therefore, it was investigated whether anatomical reduction would best be achieved by transfixation in neutral position or supination of the forearm. MATERIALS AND METHODS: Twelve cadaveric upper limbs were examined before dissection of the DRUJ stabilizing ligaments and after closed transfixation in both positions by C-arm cone-beam CT. Whether this was first done in neutral position or in supination was randomized. The change in the radioulnar ratio (RR) in percentage points (%points) was analyzed using Student's t-test. RR was used since it is a common and sensitive method to evaluate DRUJ reduction, expressing the ulnar head's position in the sigmoid notch as a length ratio. RESULTS: The analysis showed an increased change in RR in neutral position with 5.4 ± 9.7%points compared to fixation in supination with 0.2 ± 16.1%points, yet this was not statistically significant (p = 0.404). CONCLUSIONS: Neither position leads to a superior reduction in general. However, the result was slightly closer to the anatomical position in supination. Thus, transfixation of the DRUJ should be performed in the position in which reduction could best be achieved and based on these data, that tends to be in supination. Further studies are necessary to validate these findings and to identify influential factors.


Assuntos
Antebraço , Instabilidade Articular , Humanos , Supinação , Pronação , Fenômenos Biomecânicos , Articulação do Punho/cirurgia , Cadáver , Instabilidade Articular/cirurgia
14.
J Bodyw Mov Ther ; 37: 170-176, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38432801

RESUMO

BACKGROUND: ː Early detection of loss of proprioception is essential to prevent injury and maintain professional work activities. However, although many different methods are present for wrist proprioception measurement, these methods' validity and reliability studies are quite limited. OBJECTIVE: To compare the validity and reliability of the goniometer, inclinometer, and joint position sense goniometer methods used in measuring wrist active joint position sense (AJPS). METHODS: ː Thirty-two volunteer healthy participants (64 wrists) between the ages of 19-31 (mean age:23,34 ± 3,84) were included in the study. Wrist AJPS was assessed with an isokinetic dynamometer as a reference standard in addition to an inclinometer, goniometer, and joint position sense goniometer (JPSG). Spearman's Correlation Coefficient was used for validity analysis, and Intraclass Correlation Coefficient (ICC3,1) was used to analyze test-retest reliability. RESULTS: ː It was found that the goniometer (p < 0.001, r = 0.529) is a moderately valid method to assess active wrist joint position sense. The JPSG (p < 0.001, r = 0.432) and inclinometer (p = 0.005, r = 0.350) have weak validity. According to the results of ICC3,1 analysis, the goniometer (p < 0.001, ICC3,1 = 0.422) and JPSG (p < 0.001, ICC3,1 = 0.369) were found to have poor reliability in assessing wrist AJPS, and the inclinometer (p = 0,183, ICC3,1 = 0,114) was not found as a reliable method. CONCLUSIONS: ː Our results suggest that the JPSG and inclinometer should not be used in the wrist active joint position sense evaluation because of weak validity and poor reliability. The goniometer can be used in clinics and academic research to evaluate wrist joint position sense if the rater lacks a reliable and valid measurement tool.


Assuntos
Articulação do Punho , Punho , Humanos , Adulto Jovem , Adulto , Recém-Nascido , Reprodutibilidade dos Testes , Propriocepção , Terapia por Exercício
15.
Ann Ital Chir ; 95(1): 78-90, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38469615

RESUMO

BACKGROUND: To compare the clinical effects between wrist arthroscopy-assisted open reduction plus internal fixation, using the triangular fibrocartilage complex (TFCC) as an example, and simple open reduction plus internal fixation in the treatment of distal radius fractures (DRFs). The study aims to assess the efficacy of arthroscopic-assisted open reduction and internal fixation in treating distal radius fractures. METHODS: The study utilized a retrospective cohort research approach, involving 60 patients treated at Binzhou Medical University Hospital between August 2021 and October 2022. These patients met the specified criteria and underwent two distinct surgical procedures for DRFs. Prior to surgery, thorough communication was established with the patients to elucidate the advantages, risks, and associated costs of wrist arthroscopy, and informed consent was obtained. Subsequent to the surgeries, postoperative follow-up was conducted to evaluate the variances between the two treatment modalities. Postoperative analysis and assessment encompassed the patients' Visual Analogue Scale (VAS) scores, Cooney wrist scores, grip strength of the affected limb (in comparison with the healthy side), wrist range of motion, and the frequency of intraoperative fluoroscopy usage. RESULTS: No surgical complications were observed among all patients. They were followed up for an average duration of (12.1 ± 1.3) months postoperatively, during which all fractures healed successfully. Within the treatment group, arthroscopy detected 14 cases of TFCC tears during the operation, all of which were repaired under a microscope. Conversely, physical examination identified three cases of TFCC injury in the control group, which were treated via incision and suture. At the 3-month postoperative mark, the treatment group exhibited significantly superior comprehensive scores for wrist pain, grip strength, and wrist range of motion compared to the control group (p < 0.05). Cooney's comprehensive wrist joint scoring yielded the following results: treatment group - excellent in 21 cases, good in five cases, and moderate in four cases; control group - excellent in 16 cases, good in nine cases, and moderate in five cases. CONCLUSION: Wrist arthroscopy-assisted surgery facilitates precise reduction of the articular surface and alleviation of intraarticular congestion. Moreover, it enables evaluation and repair of concurrent intra-articular injuries such as TFCC tears and other tissue injuries, thereby reducing the likelihood of chronic wrist pain. Consequently, this technique should be deemed valuable in clinical practice owing to its outstanding clinical efficacy.


Assuntos
Fraturas do Rádio , Fibrocartilagem Triangular , Fraturas do Punho , Traumatismos do Punho , Humanos , Fibrocartilagem Triangular/cirurgia , Fibrocartilagem Triangular/lesões , Punho , Artroscopia/métodos , Estudos Retrospectivos , Traumatismos do Punho/cirurgia , Fraturas do Rádio/cirurgia , Articulação do Punho/cirurgia , Resultado do Tratamento , Dor
16.
Artigo em Inglês | MEDLINE | ID: mdl-38442043

RESUMO

OBJECTIVE: A pathological tremor (PT) is an involuntary rhythmic movement of varying frequency and amplitude that affects voluntary motion, thus compromising individuals' independence. A comprehensive model incorporating PT's physiological and biomechanical aspects can enhance our understanding of the disorder and provide valuable insights for therapeutic approaches. This study aims to build a biomechanical model of pathological tremors using OpenSim's realistic musculoskeletal representation of the human wrist with two degrees of freedom. METHODS: We implemented a Matlab/OpenSim interface for a forward dynamics simulation, which allows for the modeling, simulation, and design of a physiological H∞ closed-loop control. This system replicates pathological tremors similar to those observed in patients when their arm is extended forward, the wrist is pronated, and the hand is subject to gravity forces. The model was individually tuned to five subjects (four Parkinson's disease patients and one diagnosed with essential tremor), each exhibiting distinct tremor characteristics measured by an inertial sensor and surface EMG electrodes. Simulation agreement with the experiments for EMGs, central frequency, joint angles, and angular velocities were evaluated by Jensen-Shannon divergence, histogram centroid error, and histogram intersection. RESULTS: The model emulated individual tremor statistical characteristics, including muscle activations, frequency, variability, and wrist kinematics, with greater accuracy for the four Parkinson's patients than the essential tremor. CONCLUSION: The proposed model replicated the main statistical features of subject-specific wrist tremor kinematics. SIGNIFICANCE: Our methodology may facilitate the design of patient-specific rehabilitation devices for tremor suppression, such as neural prostheses and electromechanical orthoses.


Assuntos
Discinesias , Tremor Essencial , Doença de Parkinson , Humanos , Tremor , Punho/fisiologia , Articulação do Punho , Fenômenos Biomecânicos
17.
Curr Med Imaging ; 20: 1-9, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38389340

RESUMO

BACKGROUND: Rheumatoid Arthritis Magnetic Resonance Imaging Score (RAMRIS) is usually used for the semi-quantitative evaluation of joint changes in Rheumatoid Arthritis (RA). However, this method cannot evaluate early changes in bone marrow edema (BME). OBJECTIVE: To determine whether T1 mapping of wrist BME predicts early treatment response in RA. METHODS: This study prospectively enrolled 48 RA patients administered oral anti-rheumatic drugs. MRI of the most severely affected wrist was performed before and after 4 (48 patients) and 8 weeks of treatment (38 patients). Mean T1 values of BME in the lunate, triangular, and capitate bones; RAMRIS for each wrist; Erythrocyte-Sedimentation Rate (ESR); and 28-joint Disease Activity Score (DAS28)-ESR score were analyzed. Patients were divided into responders (4 weeks, 30 patients; 8 weeks, 32 patients) and non-responders (4 weeks, 18 patients; 8 weeks, 6 patients), according to EULAR response criteria. Receiver operating characteristic (ROC) curves were used to evaluate the efficacy of T1 values. RESULTS: ESR and DAS28-ESR were not correlated with T1 value and RAMRIS at each examination (P > 0.05). Changes in T1 value and DAS28-ESR relative to the baseline were moderately positively correlated with each other at 4 and 8 weeks (r = 0.555 and 0.527, respectively; P < 0.05). At 4 weeks, the change and rate of change in T1 value significantly differed between responders and non-responders (-85.63 vs. -19.92 ms; -12.89% vs. -2.81%; P < 0.05). The optimal threshold of the rate of change in T1 value at 4 weeks for predicting treatment response was -5.32% (area under the ROC curve, 0.833; sensitivity, 0.900; specificity, 0.667). CONCLUSION: T1 mapping provides a new imaging method for monitoring RA lesions; changes in wrist BME T1 values reflect early treatment response.


Assuntos
Artrite Reumatoide , Sinovite , Humanos , Sinovite/diagnóstico , Sinovite/patologia , Artrite Reumatoide/diagnóstico por imagem , Artrite Reumatoide/tratamento farmacológico , Imageamento por Ressonância Magnética/métodos , Articulação do Punho/diagnóstico por imagem , Articulação do Punho/patologia , Edema/diagnóstico , Edema/patologia , Espectroscopia de Ressonância Magnética
18.
Hand Surg Rehabil ; 43(1): 101610, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38393765

RESUMO

The gold-standard for bone, ligament and joint surgery in the wrist is locoregional anesthesia in most countries. Wide-Awake Local Anesthesia No Tourniquet (WALANT) is commonly used for simple soft-tissue hand surgery procedures such as carpal tunnel or trigger finger release, and can now also be safely used in procedures such as proximal row carpectomy, scapholunate ligament repair or partial wrist fusion, to name but a few. This article describes the use of WALANT for complex surgery in the wrist. WALANT surgery offers many known benefits, such as enhanced patient safety and comfort, simplified perioperative process and avoidance of anesthesia-related risks, and also allows the surgeon to perform intraoperative testing of the repaired structures. Thus, the surgeon can tailor the rehabilitation program and shorten recovery time. We describe detailed guidelines for performing WALANT procedures safely and effectively, making it a favorable option for complex surgeries in the wrist.


Assuntos
Anestesia Local , Síndrome do Túnel Carpal , Humanos , Anestesia Local/métodos , Punho , Síndrome do Túnel Carpal/cirurgia , Articulação do Punho/cirurgia , Ligamentos Articulares/cirurgia
19.
J Hand Surg Am ; 49(4): 321-328, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38300191

RESUMO

PURPOSE: Recent biomechanical studies have highlighted the importance of foveal reinsertion when repairing triangular fibrocartilage complex (TFCC) injury with foveal tears. However, clinical studies comparing different repair techniques are scarce. We compared the clinical outcomes of suture anchor repair and rein-type capsular suture in patients with TFCC palmer 1B foveal tears with a minimum of 2-year follow-up. METHODS: This was a single-surgeon, single-center, retrospective, comparative study. We included patients who underwent TFCC repair surgery due to a foveal tear from December 2013 to October 2018 with a minimum follow-up of 24 months. Postoperative Quick Disabilities of Arm, Shoulder, and Hand (QuickDASH) score, Modified Mayo Wrist Score, visual analogue scale for pain, wrist range of motion, and grip strength were compared. We also measured the maximal ulnar head displacement with dynamic ultrasound to quantify distal radioulnar joint stability. RESULTS: In total, 103 patients were in the suture anchor group (group A) and 84 patients in the rein-type capsular suture group (group B). The mean follow-up time exceeded three years for both groups. There was a minimal difference regarding QuickDASH score, visual analogue scale for pain, and grip strength ratio between the two groups. The rein-type group had significantly better Modified Mayo Wrist Score. The suture anchor group showed better distal radioulnar joint stability with dynamic ultrasound, but was more limited in ulnar deviation. However, these differences are most likely clinically insignificant. CONCLUSIONS: Both suture anchor repair and rein-type capsular suture yielded satisfactory results for TFCC 1B foveal tear in a minimum of 2-year follow-up. The functional scores were similar, and no major complications or recurrent instability were noted in either group. TYPE OF STUDY/LEVEL OF EVIDENCE: Retrospective Therapeutic Comparative Investigation IV.


Assuntos
Fibrocartilagem Triangular , Traumatismos do Punho , Humanos , Fibrocartilagem Triangular/lesões , Seguimentos , Estudos Retrospectivos , Âncoras de Sutura , Articulação do Punho/cirurgia , Dor , Traumatismos do Punho/cirurgia , Artroscopia/métodos , Suturas , Técnicas de Sutura
20.
Clin Biomech (Bristol, Avon) ; 112: 106190, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38325129

RESUMO

BACKGROUND: Passive stiffness describes how easily a joint may move passively. To accurately measure wrist stiffness, an electro-oscillation device was developed. The objectives were to 1) ensuring that the measurement are free from intentional or reflex contraction, 2) analyzing how forearm anatomy affects the passive stiffness of the wrist and 3) determining the clinical practical relevance of the device. METHODS: In this prospective study, the device generated low amplitude sinusoidal motions in flexion and extension on the wrist to quantify elastic and viscous passive stiffness in voluntary orthopaedic patients. The first series of measurements was carried out in the state of voluntary relaxation, the second series of measurements was carried out after an axillary plexus anesthetic block. A matched group of healthy subjects were use for control. FINDINGS: The Electromechanical Oscillation methods effectively enable the measurement of passive joint stiffness since the stiffness values obtained show no statistically significant difference pre-post the anesthesia. The stiffness values are comparable to those of healthy subjects. The effect of forearm passive structure, estimated by the perimeter of the forearm, influences the passive stiffness of the wrist, mainly the viscous component. INTERPRETATION: The use of sinusoidal oscillation was well accepted by the participants, demonstrating its usefulness and applicability in a clinical setting. This work serves as a foundation for future investigations of orthopaedic and/or neurological pathological conditions characterized by abnormal passive joint stiffness of the wrist. It paves the way for its use as a diagnostic, prognostic, and monitoring tool in these pathologies.


Assuntos
Articulação do Punho , Punho , Humanos , Estudos Prospectivos , Antebraço , Amplitude de Movimento Articular , Músculo Esquelético
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...